Pressure sensors find it’s ways into many of today’s IoT Solutions.
Pressure
Pressure Sensor Applications
HVAC
Larger HVAC installations that contains boiler rooms requires constant pressure monitoring as part of alarm system
Chemical
Chemical manufacturing requires specific pressure levels to be maintained for quality and efficient production
Altitude
Various solutions where altitude measurement can be determined indirectly by using pressure sensors
Medical
Monitoring the pressure levels in oxygen tanks.
Industrial
As part of Industry 4.0, various parts of factories needs to be monitored for pressure levels to implement digital twins.
Technical Specifications
Technical Specifications
| |
Power Supply | Internal Primary Battery |
Communication | LoRaWAN |
Bands | 868MHz, 865MHz, 915MHz |
Tx power level | 20dBm ± 2dBm |
Receiver sensitivity | -137dBm |
Battery | 3.6V, 2.1AH |
Battery type | Non-Rechargeable, AA Size |
Temp measurement range | -20°C to +85°C [units °C]; ±0.3°C |
Operating Temperature | -20°C to +85°C |
Enclosure | IP54 Rated |
Sensor response time | 3 Secs |
Size | 80mm x 45mm x25mm |
Power Consumption | <10 μA in Sleep Mode. 125mA Typ. Transmit Mode <4mA in Sensor Sampling Mode |
Battery backup time | > 2 years* @ 2.1AH @ SF10 network Default operating mode comes with Report Interval 1 Hour |
Product operational life | 7 years |
Specifications |
|
Power Supply |
Internal Secondary Battery |
Communication |
LTE, 3G, 2G |
Bands |
Global B1, B5, B8 |
Data rate |
14.4Mbps, 5.76Mbps/ 384kbps, 384kbps |
Tx power level |
33dBm ± 2dBm |
Receiver sensitivity |
-108.5dBm |
Battery |
4.2V, 3.5AH Li-po |
Battery type |
Rechargeable |
Temp measurement range |
-20°C to +85°C [units °C]; ±0.3°C |
Operating Temperature |
-20°C to +65°C |
Enclosure |
IP66 Rated [Food Grade variant available] |
Sensor response time |
3 Secs |
Data Storage |
3-week data [latest 3-week data stored in Memory] |
Power Consumption |
<10 μA in Sleep Mode. 517mA Typ. Transmit Mode <4mA in Sensor Sampling Mode [Approx. 2 Sec]. |
Battery backup time |
Up to 45 days* @ 2.8AH Default operating mode comes with Report Interval 1 Hour, sampling interval 1 mint |
Battery charge cycles |
>300 [Discharge at -20°C to +65°C & Charge at 25°C] |
Product operational life |
7 years** |
Specifications |
|
Power Supply |
Internal Secondary Battery |
Communication |
Cat – M1, NB-IoT, 2G |
Bands |
Cat – M1 & NB-IoT : LTE FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/ B19/B20/B26/B28 LTE TDD: B39 (For Cat M1 Only) 2G: 850/900/1800/1900MHz |
Data rate |
Cat M1: Max. 375Kbps (DL), Max. 375Kbps (UL) Cat NB1: Max. 32Kbps (DL), Max. 70Kbps (UL) EDGE: Max. 296Kbps (DL), Max. 236.8Kbps (UL) GPRS: Max. 107Kbps (DL), Max. 85.6Kbps (UL) |
Tx power level |
Max Power 23dBm |
Receiver sensitivity |
-107dBm @Cat M1, 1.4MHz Bandwidth, CE Mode A -113dBm @Cat NB1, CE Level 0 |
Battery |
4.2V, 3.5AH Li-po |
Battery type |
Rechargeable |
Temp measurement range |
-20°C to +85°C [units °C]; ±0.3°C |
Operating Temperature |
-20°C to +65°C |
Enclosure |
IP66 Rated [Food Grade variant available] |
Sensor response time |
3 Secs |
Data Storage |
3-week data [latest 3-week data stored in Memory] |
Power Consumption |
Power Saving Mode: 10uA Idle State: 16mA @DRX=1.28s 15mA @e-I-DRX=20.48s Sleep State: 2.3mA @DRX=1.28s 1.7mA @e-I-DRX=20.48s LTE Connected Mode (Avg.): 65mA @0dBm 66mA @10dBm 78mA @23dBm |
Battery backup time |
Up to 45 days* @ 2.8AH Default operating mode comes with Report Interval 1 Hour, sampling interval 1 mint |
Battery charge cycles |
>300 [Discharge at -20°C to +65°C & Charge at 25°C] |
Product operational life |
7 years** |
Specifications |
|
Power Supply |
Internal Secondary Battery |
Communication |
BLE |
Versions |
4.0 / 4.2 /5.0 |
Pairing |
Yes |
Receiver sensitivity |
-96dBm |
Battery |
Standard coin cell battery |
Battery type |
Non Rechargeable |
Temp measurement range |
-20°C to +85°C [units °C]; ±0.3°C |
Operating Temperature |
-20°C to +65°C |
Enclosure |
IP66 Rated [Food Grade variant available] |
Sensor response time |
3 Secs |
Data Storage |
3-week data [latest 3-week data stored in Memory] |
Power Consumption |
6.5mA Rx mode; 9.6mA Tx mode, 1.2uA Sleep mode |
Battery backup time |
Up to 1 year* Default operating mode comes with Report Interval 1 Hour, sampling interval 1 mint |
Battery charge cycles |
NA |
Product operational life |
5 years** |